Building code and good design practices are critical in the bathroom. The bathroom is a dense conglomeration of water supply and drain pipes, electricity, and slippery surfaces—all crammed within a tiny space often no more than 150 square feet in size. Next to the kitchen, it is important to pay attention to spacing and code issues in the bathroom.

Bathroom code and best design practices are not onerous restrictions designed to squeeze your wallet dry and hamper your creativity. Some parts of the bathroom building code and practices may seem trivial. But in many ways, bathroom code can be a useful guide as to what goes where and how to space the elements during your bathroom remodel.

Bathroom Sink Spacing and Design

  • Sink sidewall placement: Sinks should be spaced at least 4 inches from sidewalls. One reason is that sinks produce water, and water should be kept away from moisture-sensitive drywall. Placing the edge of the sink 4 inches or more from the sidewalls also provides the user with more room, and it gives enough room for the plumbing supply and drain pipes below.
  • Sink front clearance: Bathroom sinks should have a minimum of 21 inches of clearance in front. This requirement gives the user enough room to work.
  • Double sink placement: If you want to place two sinks side by side, make certain that they are at least 4 inches apart from one another, measured from adjacent edges.
  • Bathroom sinks and bathtubs: Bathroom design practices or code typically recommend that sinks should be at least 4 inches away from bathtubs.

Toilet Spacing and Design

  • Toilet front clearance: Bathroom building code or design practices recommend that toilets need at least 21 inches of clearance in front of the toilet. Opting for 30 inches of room provides a more comfortable space.
  • Toilet side clearance: Side-to-side clearance for a toilet is a minimum of 15 inches from the center line of the toilet to the nearest obstruction. However, 18 inches provides better clearance and is considered a preferred design practice.

Tip

Many communities require water-saving devices on the toilet. New toilets often have these devices pre-installed. Most modern toilets use 1.28 gallons per flush or less while still providing equal or superior performance compared to older 1.6 GPF toilets.

Shower and Bathtub Code and Spacing Practices

  • Shower sizes: Shower maximum sizes are not mandated. In fact, the entire bathroom can be a shower. But minimum sizes are regulated. Shower floor minimum size is usually mandated to be at least 30 inches square; that is, 30 inches by 30 inches.
  • Shower door clearance: Because shower doors are usually glass and can break and because of other access issues, bathroom code states that shower doors need to have at least 24 inches of opening clearance. This is also a safety issue because users who are forced to slip around narrow door openings are more prone to slipping on the floor.
  • Anti-scald devices: Both showers and bathtubs must have anti-scald devices. Older shower and bath fixtures may not have this feature. All current fixtures will have this.

Tip

Some communities require water-saving showerheads that limit flow. Inexpensive inserts can be installed between the showerhead and the water pipe to limit the flow of water. Most showerheads use 2.5 gallons of water per minute. Look for water-saving showerheads with the EPA's WaterSense badge that use no more than 2 gallons per minute.

Ventilation and Electrical Code and Design

Bathroom code as it relates to electricity is very important due to the possibility of shocks and fire, especially since water is present in bathrooms.

  • Lights over tubs and showers: All lights over bathtubs and showers are required to be vapor- and waterproof. These are identified by a clear or opaque cover over the bottom of the light: the bulb will not be exposed.
  • GFCI outlets: All outlets must be GFCI (ground fault current interrupter) outlets. GFCI protection can be supplied at each outlet or at one point upstream from one or more outlets.
  • Switch distance from bathing facilities: Bathroom code discourages bathers from standing in tubs or showers while turning switches on or off, so switches must be 60 inches minimum from these places.
  • Bathroom ventilation: Bathrooms do not need to have fans, but they are required to have ventilation. This ventilation can be either in the form of a window at least 3 square feet in area or a bathroom fan capable of pulling out at least 50 cubic feet of air per minute. Even if the bathroom does have an openable window, it's still a good idea to supply mechanical ventilation.

About Bathroom Code and Design Practices

Though based on the framework of model codes, the bathroom code is not the same everywhere. Codes in Maine may not necessarily be the same as codes in Florida. Not only that, but municipalities can add their twists to the code to adapt to local needs.

Bathroom codes in this guide can point you in a general direction. Check with your permitting department to make sure that this code information is applicable to your home and situation. This is not an exhaustive guide; these are only the most popular elements that most homeowners tend to be interested in.

Tip

Use larger tiles, bold colors, and luxurious fixtures in bathrooms of all sizes to express design savvy and creativity with maximum visual impact without violating any bathroom codes.

Good bathroom design practices are not building code. Rather, these are helpful guidelines issued by the National Kitchen and Bath Association, a "non-profit trade group that promotes professionalism in the kitchen and bath industry," according to its mission statement. The NKBA has been a leading voice in the kitchen and bath design industry since 1963.